ASIC Miner Silencer Gen2 – Noise Reduction Blower

SKU: PARTS-3889

Reduce high-frequency ASIC fan noise while maintaining strong airflow and efficient cooling. Compatible with popular Antminer, WhatsMiner, Avalon and IceRiver models.

  • Up to ~10°C lower temperatures
  • 1300 m³/h airflow
  • Brushless DC motor
  • Stepless speed control
2-Year Warranty
Fast Worldwide Delivery

In stock

200,00 

(excl. VAT)

Payment Methods:
amex-outline Created with Sketch. mastercard maestro
Category: Brand:

Full description

Reduce ASIC miner noise without sacrificing cooling

The ASIC Miner Silencer Gen2 is a high-airflow blower system designed
to replace the sharp, high-frequency noise produced by standard ASIC cooling fans.

With airflow of up to 1300 m³/h, stepless speed control and a brushless
DC motor, the blower provides powerful cooling while producing a smoother and more
manageable airflow sound.

It is suitable for many popular Antminer, WhatsMiner, Avalon and IceRiver
models and can be used as part of a quieter and more efficient ASIC cooling setup.

ASIC Miner Silencer Gen2 installed on an Antminer

Close-up of ASIC miner silencer blower housing and fan

Why upgrade to the Gen2 ASIC Miner Silencer?

Reduce high-frequency fan noise
Replace the characteristic high-pitched sound of standard ASIC fans with
lower-frequency airflow noise.

Powerful airflow
Up to 1300 m³/h of airflow helps move heat away from the miner efficiently.

Better temperature control
In suitable installations, improved airflow can help reduce operating temperatures
by approximately up to 10°C, depending on the miner and operating conditions.

Adjustable performance
Stepless speed control lets you balance airflow, cooling performance and noise.

Efficient brushless DC motor
Stable operation with lower power consumption than many traditional AC blower solutions.

Designed for real ASIC mining setups

The blower connects to the miner through a dedicated air shroud, replacing the need
for several small high-RPM cooling fans.

This allows a much larger volume of air to pass through the miner while simplifying
the airflow path. The exact installation method depends on the ASIC model and shroud configuration.

Close-up of ASIC Miner Silencer Gen2 connected to an Antminer
ASIC Miner Silencer Gen2 blower front view

Compatible with popular ASIC miners

The Gen2 blower system can be used with a wide range of ASIC miners when paired with
the correct air shroud and installation components.

Commonly supported families include:

Bitmain Antminer

S21 / S21 Pro / S21 XP / S21+ / T21 / L9 / S19 series and other compatible models.

MicroBT WhatsMiner

M60 series / M50 series / M30 / M31 / M32 / M20 / M21 and compatible models.

Canaan Avalon

A15 / A14 / A13 / A12 / A11 series and compatible models.

IceRiver

Selected AL and KS series miners, including AL3, KS5M, KS5L, KS3 series and others.

Not sure if it fits your miner?
Contact us before ordering and tell us your exact ASIC model.
We will help you check compatibility.

One blower instead of multiple high-RPM fans

Standard ASIC miners typically rely on several compact fans running at very high RPM.
The Gen2 blower uses a different approach: a large centrifugal blower moves a high
volume of air through the miner.

The result is a cooling setup designed to reduce the unpleasant high-frequency fan
noise while maintaining strong airflow through the hashboards.

ASIC Miner Silencer Gen2 next to an Antminer for size comparison

Technical specifications

Motor Brushless DC
Input voltage 220 V
Maximum power 162 W
Maximum airflow 1300 m³/h
Air velocity Up to 12 m/s
Outlet diameter 150 mm
Noise level Approx. 78 dB
Speed control Stepless
Application ASIC miner cooling & noise reduction

ASIC Miner Silencer Gen2 airflow shroud and blower inlet

Simple concept, model-specific installation

Installation generally involves removing or bypassing the original cooling fans,
fitting the appropriate air shroud and connecting the blower system.

Because ASIC miners differ in dimensions, fan monitoring and airflow configuration,
the required accessories may vary between models.

Before installation, always verify:

  • Correct shroud compatibility
  • Sufficient airflow direction
  • Miner fan monitoring requirements
  • Secure mounting
  • Operating temperatures after installation

Frequently asked questions

Does the blower make an ASIC miner completely silent?
No. ASIC mining equipment still produces airflow and operating noise.
The main advantage is reducing the sharp, high-frequency sound generated
by standard high-RPM ASIC fans.
Can it reduce ASIC miner temperatures?
Improved airflow can reduce operating temperatures. Tests with compatible setups
have shown reductions of approximately up to 10°C, although actual results depend
on the miner, ambient temperature, airflow and installation.
Does it replace the original ASIC fans?
In most compatible installations, the blower is used as the primary cooling airflow
source. The exact configuration depends on the miner model.
Is it compatible with Antminer S19 and S21 miners?
The system supports multiple models from the S19 and S21 families when used
with the appropriate shroud and installation configuration.
Can it be used with WhatsMiner or Avalon miners?
Yes, many WhatsMiner and Avalon models can also be used with this type of blower system.
Contact us with the exact model before ordering if you are unsure.
Do I need custom firmware?
This depends on the miner and how its fan monitoring is handled.
Some configurations may require a fan simulator or firmware settings
to prevent fan-related errors.
What exactly is included?
Package contents may depend on the selected configuration.
Please check the product option or contact us if you require a specific
shroud or accessory.

Not sure if this blower fits your ASIC?

Send us your miner manufacturer and exact model before ordering.

Our team will help you confirm compatibility and choose the correct configuration.

Contact us

Reviews

There are no reviews yet.

Be the first to review “ASIC Miner Silencer Gen2 – Noise Reduction Blower”

Your email address will not be published. Required fields are marked *